Download IconPrint Icon

BayCom® FO outdoor cables with metallic armouring

A-DF(ZN)2Y(SR)2Y

direct burial acc. to DIN VDE and Bayka standard


PT242_A-DQ(ZN)2Y(SR)2Y_verseilt_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung20-UV-beständig46-Robust44-Nagetierschutz36-Längswasserdicht51-Verlegung -10

 


Standards

DIN VDE 0888-3, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Single-mode fibre
G.652.D (Standard)
G.652.D (BayCom *)
G.657.A1

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
E9/125 0,36F3,5 0,21H18
Graded index fibre
OM2
OM3
OM4

G50/125 2,5B500 0,7F500
G50/125 2,5B1500 0,7F500
G50/125 2,5B3500 0,7F500
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage
laying
operation


-40 to +70
-10 to +60
-30 to +70

Application

FO outdoor cable with metallic rodent protection (steel channel sheath), as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:

  • Rugged outdoor cable with reinforced sheath.
    This cable is optimised for construction and underground installation and complies with the long experience of fibre optic and telecommunication cables laid in the ground (VDE 0888, VDE 0816 and similar).

The following applies to FO cables acc. to the company standard BayCom LWL01:

  • Quality assurance through VDE Certificate/VDE manufacturing report
  • 2 rip cords facilitate installation

The following applies additionally for BayCom* FO cables

Improved optical properties compared to standard fibres

Type Designation Codes

A outdoor cable
D loose tube, filled
Q cable core dry, longitudinally watertight
(ZN) non-metallic stress relief elements
2Y inner sheath made of polyethylene, PE
(SR) corrugated steel tape armouring
2Y outer sheath made of polyethylene, PE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DQ(ZN)2Y(SR)2Y 12x12 E9/125
A-DQ(ZN)2Y(SR)2Y 12x12 E9/125 G.652.D BayCom*


Print Icon

BayCom® FO outdoor cables with metallic armouring

A-DF(ZN)2Y(SR)2Y

direct burial acc. to DIN VDE and Bayka standard

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DQ(ZN)2Y(SR)2Y   1x 2 E9/125 (VS) 5830210 2 15 208 300 240 320 6.0
A-DQ(ZN)2Y(SR)2Y   2x 2 E9/125 5830220 4 15 205 300 230 310 6.0
A-DQ(ZN)2Y(SR)2Y   4x 2 E9/125 5830230 8 15 210 300 230 310 6.0
A-DQ(ZN)2Y(SR)2Y   6x 2 E9/125 5830240 12 15 210 300 230 310 6.0
A-DQ(ZN)2Y(SR)2Y   6x 4 E9/125 5830250 24 15 210 300 240 310 6.0
A-DQ(ZN)2Y(SR)2Y   6x 6 E9/125 5830260 36 15 210 300 230 310 6.0
A-DQ(ZN)2Y(SR)2Y   4x12 E9/125 5830270 48 15 210 300 230 310 6.0
A-DQ(ZN)2Y(SR)2Y   5x12 E9/125 5830280 60 15 210 300 230 310 6.0
A-DQ(ZN)2Y(SR)2Y   8x12 E9/125 5830300 96 17 260 400 260 350 7.5
A-DQ(ZN)2Y(SR)2Y  12x12 E9/125 5830320 144 21 385 550 330 440 12.0
The part numbers in the table are for fibers after G.652.D (standard)
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.