Download IconPrint Icon

BayCom® FO micro cables for microducts, G.652.D

A-DQ(ZN)2Y (HD) Microduct

central loose tube - cable-∅ 3,9mm acc. to Bayka company standard



06-Einblasoptimiert20-UV-beständig36-Längswasserdicht50-Verlegung -5



DIN VDE 0888-3, EN 60794-3 (VDE 0888-108), ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1, BayCom LWL01.

The cables are compliant to RoHS EU Directive 2011/65/EU - RoHS 2.0 and Regulation No 1907/2006 (REACH), current as of 20.06.2013.

Technical Data

Single-mode fibre
G.652.D (Standard)

E9/125 0,36F3,5 0,22H18
E9/125 0,36F3,5 0,21H18
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage

-30 to +70
-5 to +50
-20 to +70

Installation instructions:
The cable must be clean and dry. Optimum temperature of the cable + 5°C to + 20°C.
Protect from sun and heat during blowing.


Metal-free FO micro cable for blowing into microducts, for FTTH networks as termination and connection cable in local networks, PBXs, for telephony and data transmission.

The micro cable is characterized by an extremely compact and rugged design. The cable is UV-resistant and water-tight and guarantees high quality of the transmission network and a long life.

The bending stiffness / flexibility and low friction HDPE outer sheath is optimally adjusted to the microducts so great blow in can be achieved.

Type Designation Codes

A outdoor cable
D loose tube, filled
Q cable core with swellable tape - water-tight
(ZN) non-metallic strength members
2Y outer sheath made of high density polyethylene, HDPE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-D(ZN)2Y (HD) Micro 1x12 E9/125 G.652.D

Print Icon

BayCom® FO micro cables for microducts, G.652.D

A-DQ(ZN)2Y (HD) Microduct

central loose tube - cable-∅ 3,9mm acc. to Bayka company standard

Product Bayka Order No. No. of fibers Outer ∅
Net weight
Max. tensile force Bending radius repeated Bending radius one-off
mm kg/km daN min. mm min. mm  
A-DQ(ZN)2Y (HD)       2 E9/125  Microkabel G.652 D  AD:3,9mm 5999090 2 4 10 40 80 60
A-DQ(ZN)2Y (HD)       4 E9/125  Microkabel G.652 D  AD:3,9mm 5919260 4 4 10 40 80 60
A-DQ(ZN)2Y (HD)       6 E9/125  Microkabel G.652 D  AD:3,9mm 5999130 6 4 10 40 80 60
A-DQ(ZN)2Y (HD)       8 E9/125  Microkabel G.652 D  AD:3,9mm 5999160 8 4 10 40 80 60
A-DQ(ZN)2Y (HD)      12 E9/125  Microkabel G.652 D  AD:3,9mm 5919270 12 4 10 40 80 60
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
Other designs, fitted lengths and larger delivery lengths on request.