Download IconPrint Icon

BayCom® FO micro cables for microducts, G.657.A1

A-DQ(ZN)2Y (HD) Microduct

stranded loose tube - 1000 N acc. to Bayka company standard


PT402_A-DQ(ZN)2Y_Mini_en
RoHS_LogoREACH_LogoCE_Logo

 

06-Einblasoptimiert36-Längswasserdicht50-Verlegung -5

 


Standards

DIN VDE 0888-3, EN 60794-3 (VDE 0888-108), ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1, BayCom LWL01.

The cables are compliant to RoHS EU Directive 2011/65/EU - RoHS 2.0 and Regulation No 1907/2006 (REACH), current as of 20.06.2013.

Technical Data

Single-mode fibre
G.652.D (Standard)
G.657.A1

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage
laying
operation


-30 to +60
-5 to +50
-30 to +60

Installation instructions:
The cable must be clean and dry. Optimum temperature of the cable + 5°C to + 20°C.
Protect from sun and heat during blowing.

Application

Metal-free FO micro cable for blowing into microducts, for FTTH networks as termination and connection cable in local networks, PBXs, for telephony and data transmission.

The micro cable is characterized by an extremely compact and rugged design. The cable is UV-resistant and water-tight and guarantees high quality of the transmission network and a long life.

The bending stiffness / flexibility and low friction HDPE outer sheath is optimally adjusted to the microducts so great blow in can be achieved.

Type Designation Codes

A outdoor cable
D loose tube, filled
Q cable core with swellable tape - water-tight
(ZN) non-metallic strength members
2Y outer sheath made of high density polyethylene, HDPE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DQ(ZN)2Y (HD) Micro 12x12 E9/125 G.652.D


Print Icon

BayCom® FO micro cables for microducts, G.657.A1

A-DQ(ZN)2Y (HD) Microduct

stranded loose tube - 1000 N acc. to Bayka company standard

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius repeated Bending radius one-off
mm kg/km daN min. mm min. mm  
A-DQ(ZN)2Y (HD)    2x12 E9/125  Minikabel G.657 A1  AD:6,0mm 5919530 24 6 30 100 120 90
A-DQ(ZN)2Y (HD)    4x12 E9/125  Minikabel G.657 A1  AD:6,0mm 5919540 48 6 30 100 120 90
A-DQ(ZN)2Y (HD)    6x12 E9/125  Minikabel G.657 A1  AD:6,0mm 5919560 72 6 30 100 120 90
A-DQ(ZN)2Y (HD)    8x12 E9/125  Minikabel G.657 A1  AD:6,4mm 5919580 96 6 35 100 130 100
A-DQ(ZN)2Y (HD)   12x12 E9/125  Minikabel G.657 A1  AD:8,5mm 5919590 144 9 50 100 170 130
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.