Print Icon

BayEnergy® Railway power cables, aluminium

(N)A2XS2Y / (N)A2XS(F)2Y
PE-Mantel

Railway power cables 1.8/3 kV acc. to IEC 60502-1, resp. based on DIN VDE 0271


CT371_NA2XS2Y_NA2XS(F)2Y_Bahnstrom_en
RoHS_LogoREACH_Logo

 

08-Trogverlegung04-Rohrverlegung02-Erdverlegung10-Verlegung im Freien, UV-Schutz beachten!23-Halogenfrei53-Verlegung -20

optional

Längswasserdicht optionalFlammwidrig optionalRaucharm optionalÖlbeständig optionalUV-beständig optionalVerlegung -25 -30 -40 optional

Standards

acc. to IEC 60502-1, based on DIN VDE 0271.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

Technical Data

Rated voltage kV 1.8/3
Testing voltage kV 7
Cable temperature ºC
during laying (min)
after laying (max)


-20
+90

Max permissible operating temperature
(conductor) °C
+90
Short-circuit temperature °C +250
Current carrying capacity
acc. to HD 603 S1-1994 5G
during regular operation: table 14+15
in case of short-circuit: table 17
short-circuit duration max 5s

 

Application

Cables for special applications, e.g. as a single core railway traction current cable for direct current and alternating current. Also as a return current cable in direct current systems up to 1.8/3 kV.

Preferably for connections in overhead lines and rails, for laying in pipe conduits and trough channels and directly in the ground.

The regulations and standards of the transport services apply for the selection of railway traction current cables.

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
A conductor made of aluminium
2X insulation made of cross-linked polyethylene (XLPE)
S screen made of cooper
(F) longitudinally watertight in the screen section
2Y outer sheath made of polyethylene (PE)
RM circular conductor, stranded

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

(N)A2XS(F)2Y 1x400 RM/35 1,8/3 kV


Print Icon

BayEnergy® Railway power cables, aluminium

(N)A2XS2Y / (N)A2XS(F)2Y
PE-Mantel

Railway power cables 1.8/3 kV acc. to IEC 60502-1, resp. based on DIN VDE 0271

Product Bayka Order No. Cu No. Al-No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km kg/km mm kg/km kA daN min. mm min. mm  
(N)A2XS2Y 1x150 RM/16  1,8/3kV  (A-NF) 4723800 182 435 26 865 14.10 450 190 380
(N)A2XS2Y 1x150 RM/25  1,8/3kV  (A-NF) 4723810 283 435 26 965 14.10 450 200 390
(N)A2XS2Y 1x185 RM/16  1,8/3kV  (A-NF) 4723820 182 537 27 980 17.39 555 200 400
(N)A2XS2Y 1x185 RM/25  1,8/3kV  (A-NF) 4723830 283 537 28 1085 17.39 555 210 420
(N)A2XS2Y 1x240 RM/25  1,8/3kV  (A-NF) 4723840 283 696 30 1270 22.56 720 230 450
(N)A2XS2Y 1x300 RM/25  1,8/3kV  (A-NF) 4723850 283 870 32 1470 28.20 900 240 480
(N)A2XS2Y 1x400 RM/35  1,8/3kV  (A-NF) 4723860 394 1160 35 1910 37.60 1200 270 540
(N)A2XS2Y 1x500 RM/35  1,8/3kV  (A-NF) 4723870 394 1450 39 2250 47.00 1500 300 590
(N)A2XS(F)2Y   1x150 RM/16     1,8/3 kV   (A-NF) 4721010 182 435 26 870 14.10 450 200 390
(N)A2XS(F)2Y   1x150 RM/25     1,8/3 kV   (A-NF) 4721020 283 435 26 970 14.10 450 200 400
(N)A2XS(F)2Y   1x185 RM/16     1,8/3 kV   (A-NF) 4721030 182 537 28 985 17.39 555 210 420
(N)A2XS(F)2Y   1x185 RM/25     1,8/3 kV   (A-NF) 4721040 283 537 28 1090 17.39 555 210 420
(N)A2XS(F)2Y   1x240 RM/25     1,8/3 kV   (A-NF) 4721050 283 696 31 1275 22.56 720 230 460
(N)A2XS(F)2Y   1x300 RM/25     1,8/3 kV   (A-NF) 4721060 283 870 33 1475 28.20 900 250 490
(N)A2XS(F)2Y   1x400 RM/35     1,8/3 kV   (A-NF) 4721070 394 1160 36 1915 37.60 1200 270 540
(N)A2XS(F)2Y   1x500 RM/35     1,8/3 kV   (A-NF) 4720020 394 1450 40 2260 47.00 1500 300 600
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.