BayEnergy® Low voltage cables
GKN Alsm
3-cores based on HD 603 S1 part 7E










Standards
Cable based on CENELEC HD 603 S1 part 7E
halogen-free acc. to IEC 60 754-1
no corrosive gases acc. to DIN EN 50 267-2-3
no toxic gases acc. to DIN EN 50 305
The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2011/65/EU - RoHS 2.0 and Regulation No. 1907/2006 (REACH).
They are free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.
Technical Data
Al conductor, bare, sector-shaped, stranded | |
Conductor insulation, elastomer based on HEPR acc. to the requirements of HD 603.1 table 2C | |
Core marking acc. to HD 603 S1 part 7E L1 black L2 red L3 white |
|
Inner covering (extruded bedding) with separating strip against bonding | |
Outer conductor = protective earth (PE) Cu wires, ceander design, with Cu counter helix |
|
Outer sheath made of halogen-free, robust PE | |
Wear-resistant cable marking 2 yellow longitudinal strips, BAYKA, year / month of manufacture, 0.6/1 kV, metre marking |
|
Rated voltage U0/U kV | 0.6/1 |
Conductor resistance (direct current at 20 °C) | acc. to IEC 60228 |
Testing voltage (AC voltage, 5 min) kV acc. to HD 603.1 |
3.5 |
Temperature ranges °C continuous operation emergency operation (less than 8 h/d, less than 100 h/a) short-circuit |
≤ 90 ≤ 130 ≤ 250 |
Application
Suitable for installation in the ground, in protective conduits, cable ducts, in open air, for power stations, industry and distribution boards or low-voltage distribution systems.
Due to the cross-linked conductor insulation, particularly suitable for higher temperatures in the case of a short-circuit or overload. The PE sheath of the BayEnergy® LV mains cables is particularly robust and distinguishes itself with excellent mechanical properties and increased thermal compressive strength.
Type Designation Codes
G | conductor insulation, elastomer besed on HEPR |
K | concentric outer conductor/screen made of copper |
N | halogen-free sheath made of PE |
Alsm | Al conductor, sector-shaped, stranded |
Additional Informations
Design according to national, international and customer standards
Order Example
GKN 3x240 Alsm/150 Cu 0,6/1kV (3LPEN)
BayEnergy® Low voltage cables
GKN Alsm
3-cores based on HD 603 S1 part 7E
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.
*) CPR Construction Products Regulation Class,
DoP Declaration of Performance.
The DoP applies exclusively to Bayka cables.