Print Icon

BayEnergy® flame retardant, non corrosive cables, FRNC/LSOH

N2XH-O

1-2-cores acc. to DIN VDE 0276


AT401_N2XH-O_1x_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!16-Inhouse23-Halogenfrei24-Flammwidrig26-Raucharm50-Verlegung -5

optional

UV-beständig optional

Standards

DIN VDE 0276-604 and IEC 60502-1,
low gas corrosivity acc. to EN 50267,
low toxicity of gases acc. to DIN EN 50305,
low smoke density acc. to DIN EN 61034-2,
flame retardant acc. to IEC 60332-3, EN 50266-2-4.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

The cables are halogen-free, fire retardant and low-smoke.
(FRNC - flame retardant, non corrosive, LSOH - low smoke, zero halogen).

Technical Data

Rated voltage kV 0.6/1
Testing voltage kV 4
Cable temperature ºC
during laying (min)
after laying (max)

-5
+90
Max. permissible operating temperature (conductor) °C +90
Short-circuit temperature °C +250
Current carrying capacity
acc. to HD 603 S1-1994
during regular operation: B1
in case of short-circuit: B2
short-circuit duration max 5s
 

Application

Cable with improved behaviour in the event of fire.

For indoor and outdoor installation, in open air (protected against direct sun light), however not directly in the ground, for power stations, industry and distribution boards or subscriber networks, where mechanical damage to the cable is not expected (see DIN VDE 0298-1).

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
2X core insulation made of cross-linked polyethylene (XLPE)
H sheath made of thermoplastic, halogen-free polyolefin
O cable without green-yellow core
RE circular conductor, solid
RM circular conductor, stranded

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

N2XH-O 1x50 RM 0,6/1 kV


Print Icon

BayEnergy® flame retardant, non corrosive cables, FRNC/LSOH

N2XH-O

1-2-cores acc. to DIN VDE 0276

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
N2XH-O       1x6 RE   0,6/1 kV 4404100 58 8 110 0.86 30 60 120
N2XH-O      1x10 RE   0,6/1 kV 4404110 96 8.5 150 1.43 50 60 120
N2XH-O      1x16 RE   0,6/1 kV 4404120 154 9 210 2.29 80 70 140
N2XH-O      1x25 RM   0,6/1 kV 4404130 240 11 320 3.58 125 90 180
N2XH-O      1x35 RM   0,6/1 kV 4404140 336 12 410 5.01 175 90 180
N2XH-O      1x50 RM   0,6/1 kV 4495700 480 17 620 7.15 250 120 240
N2XH-O      1x70 RM   0,6/1 kV 4404010 672 16 730 10.01 350 120 240
N2XH-O      1x95 RM   0,6/1 kV 4404210 912 18 1000 13.59 475 130 260
N2XH-O     1x120 RM   0,6/1 kV 4407000 1152 19 1230 17.16 600 150 300
N2XH-O     1x150 RM   0,6/1 kV 4408600 1440 21 1500 21.45 750 160 320
N2XH-O     1x185 RM   0,6/1 kV 4404900 1776 23 1870 26.46 925 180 360
N2XH-O     1x240 RM   0,6/1 kV 4407300 2304 26 2410 34.32 1200 200 400
N2XH-O     1x300 RM   0,6/1 kV 4404150 2880 28 2990 42.90 1500 210 420
N2XH-O     1x400 RM   0,6/1 kV 4404160 3840 32 3850 57.20 2000 240 480
N2XH-O     1x500 RM   0,6/1 kV 4404180 4800 35 4890 71.50 2500 270 540
N2XH-O     1x630 RM   0,6/1 kV 4404280 6048 40 6310 90.09 3150 300 600
N2XH-O     2x1,5 RE   0,6/1 kV 4440884 29 11 160 0.21 15 70 140
N2XH-O     2x2,5 RE   0,6/1 kV 4440894 48 11 190 0.36 25 70 140
N2XH-O       2x4 RE   0,6/1 kV 4440814 77 12 240 0.57 40 80 160
N2XH-O       2x6 RE   0,6/1 kV 4440824 115 13 300 0.86 60 80 160
N2XH-O      2x10 RE   0,6/1 kV 4439204 192 15 420 1.43 100 90 180
N2XH-O      2x16 RE   0,6/1 kV 4440834 307 17 590 2.29 160 100 200
N2XH-O      2x25 RM   0,6/1 kV 4440844 480 21 890 3.58 250 130 260
N2XH-O      2x35 RM   0,6/1 kV 4440854 672 23 1150 5.01 350 140 280
N2XH-O      2x50 RM   0,6/1 kV 4440864 960 26 1480 7.15 500 160 320
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.