Print Icon

BayEnergy® Railway power cables, copper

N2XSH / N2XS(F)H
FRNC/LSOH

Railway power cables 1kV acc. to DIN VDE 0271


AT362_N2XS_H_Bahnstrom_Cu_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!16-Inhouse23-Halogenfrei24-Flammwidrig26-Raucharm50-Verlegung -5

 


Standards

DIN VDE 0271.

Low gas corrosivity acc. to EN 50267,
low toxicity of gases acc. to DIN EN 50305,
low smoke density acc. to DIN EN 61034-2,
flame retardant acc. to IEC 60332-3, EN 50266-2-4.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

The cables are halogen-free, fire retardant and low-smoke.
(FRNC - flame retardant, non corrosive, LSOH - low smoke, zero halogen).

Technical Data

Rated voltage kV 0.,6/1
Testing voltage kV 4
Cable temperature ºC
during laying (min)
after laying (max)

-5
+90
Max permissible operating temperature (conductor) °C +90
Short-circuit temperature °C +250
Current carrying capacity
acc. to HD 603 S1-1994 5G
during regular operation: table 14+15
in case of short-circuit: table 17 short-circuit duration max 5s
 

Application

Cables for special applications, e.g. as a single-core railway traction current cable for direct current and alternating current. Also as a return current cable in direct current systems up to 0.6/1 KV.

Preferably for connections in overhead lines and rails, for laying in pipe conduits and trough channels, however not directly in the ground.

The regulations and standards of the transport services apply for the selection of railway traction current cables.

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
2X insulation made of cross-linked polyethylene (XLPE)
S screen made of copper
(F) longitudinally watertight in the screen section
H sheath made of thermoplastic, halogen-free polyolefin
RM circular conductor, stranded

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

N2XSH    1x400 RM/35   0,6/1 kV  (A-SW)
N2XS(F)H  1x400 RM/35   0,6/1 kV  (A-SW)


Print Icon

BayEnergy® Railway power cables, copper

N2XSH / N2XS(F)H
FRNC/LSOH

Railway power cables 1kV acc. to DIN VDE 0271

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
N2XSH    1x150 RM/25   0,6/1kV  (A-SW) 4472020 1726 25 1960 21.45 750 190 380
N2XSH    1x185 RM/25   0,6/1kV  (A-SW) 4472040 2059 26 2285 26.46 925 200 400
N2XSH    1x240 RM/25   0,6/1kV  (A-SW) 4472050 2587 29 2835 34.32 1200 220 440
N2XSH    1x300 RM/25   0,6/1kV  (A-SW) 4472060 3163 31 3405 42.90 1500 230 460
N2XSH    1x400 RM/35   0,6/1kV  (A-SW) 4472070 4234 34 4515 57.20 2000 260 520
N2XSH    1x500 RM/35   0,6/1kV  (A-SW) 4472000 5194 38 5505 71.50 2500 290 580
N2XSH    1x500 RM/50   0,6/1kV  (A-SW) 4472080 5360 39 5670 71.50 2500 290 580
N2XSH    1x630 RM/50   0,6/1kV  (A-SW) 4472090 6569 43 6900 90.09 3150 320 640
N2XS(F)H      1x150 RM/25      0,6/1 kV   (A-SW) 4445120 1639 25 1885 21.45 750 190 380
N2XS(F)H      1x185 RM/25      0,6/1 kV   (A-SW) 4445130 2059 26 2295 26.46 925 200 400
N2XS(F)H      1x240 RM/25      0,6/1 kV   (A-SW) 4445140 2587 29 2840 34.32 1200 220 440
N2XS(F)H      1x300 RM/25      0,6/1 kV   (A-SW) 4445150 3163 31 3415 42.90 1500 240 470
N2XS(F)H      1x400 RM/35      0,6/1 kV   (A-SW) 4445100 4234 35 4520 57.20 2000 260 520
N2XS(F)H      1x500 RM/35      0,6/1 kV   (A-SW) 4445160 5194 39 5510 71.50 2500 290 580
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.