BayEnergy® flame retardant, non corrosive cables, FRNC/LSOH

N2XH-J

3 1/2-cores acc. to DIN VDE 0276


AT414_N2XH-J_4x_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!16-Inhouse23-Halogenfrei24-Flammwidrig26-Raucharm50-Verlegung -5

optional

UV-beständig optional

Standards

DIN VDE 0276-604 and IEC 60502-1,
low gas corrosivity acc. to EN 50267,
low toxicity of gases acc. to DIN EN 50305,
low smoke density acc. to DIN EN 61034-2,
flame retardant acc. to IEC 60332-3, EN 50266-2-4.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

The cables are halogen-free, fire retardant and low-smoke.
(FRNC - flame retardant, non corrosive, LSOH - low smoke, zero halogen).

Technical Data

Rated voltage kV 0.6/1
Testing voltage kV 4
Cable temperature ºC
during laying (min)
after laying (max)

-5
+90
Max. permissible operating temperature (conductor) °C +90
Short-circuit temperature °C +250
Current carrying capacity
acc. to HD 603 S1-1994
during regular operation: B1
in case of short-circuit: B2
short-circuit duration max 5s
 

Application

Cable with improved behaviour in the event of fire.

For indoor and outdoor installation, in open air (protected against direct sun light), however not directly in the ground, for power stations, industry and distribution boards or subscriber networks, where mechanical damage to the cable is not expected (see DIN VDE 0298-1).

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
2X core insulation made of cross-linked polyethylene (XLPE)
H sheath made of thermoplastic, halogen-free polyolefin
J cable with green-yellow core
RE circular conductor, solid
RM circular conductor, stranded
SM sector-shaped conductor, stranded

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

N2XH-J 3x95 SM/50 RM 0,6/1 kV


Print Icon

BayEnergy® flame retardant, non corrosive cables, FRNC/LSOH

N2XH-J

3 1/2-cores acc. to DIN VDE 0276

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
N2XH-J      3x25 RM/16 RE      0,6/1 kV 4422504 874 25 1350 3.58 455 150 300
N2XH-J      3x35 RM/16 RE      0,6/1 kV 4422514 1162 27 1720 5.01 605 160 320
N2XH-J      3x50 SM/25 RM      0,6/1 kV 4422524 1680 29 2120 7.15 875 180 360
N2XH-J      3x70 SM/35 RM      0,6/1 kV 4422534 2352 33 2880 10.01 1225 200 400
N2XH-J      3x95 SM/50 RM      0,6/1 kV 4422544 3216 37 3850 13.59 1675 220 440
N2XH-J     3x120 SM/70 RM      0,6/1 kV 4422554 4128 41 4850 17.16 2150 250 500
N2XH-J     3x150 SM/70 RM      0,6/1 kV 4422564 4992 46 5850 21.45 2600 280 560
N2XH-J     3x185 SM/95 RM      0,6/1 kV 4438104 6240 51 7350 26.46 3250 310 620
N2XH-J     3x240 SM/120 RM     0,6/1 kV 4422584 8064 57 9400 34.32 4200 340 680
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.