Print Icon

BayEnergy® Power cables, PVC insulation, PVC sheath

NYY-O

4-5-cores acc. to DIN VDE 0276


AT104_NYY-O_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung16-Inhouse10-Verlegung im Freien, UV-Schutz beachten!30-Ölbeständig_bedingt50-Verlegung -5

optional

Verlegung -25 -30 -40 optionalUV-beständig optionalÖlbeständig optional

Standards

DIN VDE 0276-603 part 3G / HD 603.1 and IEC 60502-1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are flame retardant and self-extinguishing according to DIN EN 60332-1-2 (IEC 60332-1-2) and free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

Technical Data

Rated voltage kV 0.6/1
Testing voltage kV 4
Cable temperature ºC
during laying (min)
after laying (max)


-5
  +70

Max. permissible operating temperature (conductor) °C +70
Short-circuit temperature °C +160
Current carrying capacity
acc. to HD 603 S1-1994 3G
during regular operation: table 14+15
in case of short-circuit: table 17
short-circuit duration max. 5s
 

Application

For indoor and outdoor installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where mechanical damage to the cable is not expected (see DIN VDE 0298-1).

The cables are insensitive to occasional impacts of oils and fuels.

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
Y insulation made of polyvinyl chloride (PVC)
Y outer sheath made of polyvinyl chloride (PVC)
O cable without green-yellow core
RE circular conductor, solid
RM circular conductor, stranded
SM sector-shaped conductor, stranded

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

NYY-O 4x150 SM 0,6/1 kV


Print Icon

BayEnergy® Power cables, PVC insulation, PVC sheath

NYY-O

4-5-cores acc. to DIN VDE 0276

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
NYY-O       4x1,5 RE   0,6/1kV 4045704 58 14 270 0.17 30 85 170
NYY-O       4x2,5 RE   0,6/1kV 4045804 96 14 330 0.29 50 90 180
NYY-O       4x2,5 RM   0,6/1kV 4044204 96 15 360 0.29 50 95 190
NYY-O         4x4 RE   0,6/1kV 4045904 154 17 460 0.46 80 100 200
NYY-O         4x4 RM   0,6/1kV 4044304 154 17 495 0.46 80 110 220
NYY-O         4x6 RE   0,6/1kV 4046004 230 18 575 0.69 120 110 220
NYY-O         4x6 RM   0,6/1kV 4044404 230 19 625 0.69 120 115 230
NYY-O        4x10 RE   0,6/1kV 4046104 384 20 775 1.15 200 120 240
NYY-O        4x10 RM   0,6/1kV 4046504 384 21 845 1.15 200 130 260
NYY-O        4x16 RE   0,6/1kV 4046204 614 21 1055 1.84 320 130 260
NYY-O        4x16 RM   0,6/1kV 4046804 614 24 1150 1.84 320 145 290
NYY-O        4x25 RM   0,6/1kV 4046404 960 28 1675 2.88 500 170 340
NYY-O        4x35 SM   0,6/1kV 4047104 1344 28 1925 4.03 700 170 340
NYY-O        4x50 SM   0,6/1kV 4047204 1920 31 2535 5.75 1000 190 380
NYY-O        4x70 SM   0,6/1kV 4047304 2688 36 3475 8.05 1400 215 430
NYY-O        4x95 SM   0,6/1kV 4047404 3648 40 4615 10.93 1900 245 490
NYY-O       4x120 SM   0,6/1kV 4047504 4608 44 5735 13.80 2400 270 540
NYY-O       4x150 SM   0,6/1kV 4047604 5760 48 6990 17.25 3000 295 590
NYY-O       4x185 SM   0,6/1kV 4047704 7104 53 8690 21.28 3700 325 650
NYY-O       4x240 SM   0,6/1kV 4047804 9216 60 11120 27.60 4800 360 720
NYY-O       4x300 SM   0,6/1kV 4048004 11520 65 13755 34.50 6000 395 790
NYY-O       5x1,5 RE   0,6/1kV 4051104 72 14 315 0.17 38 90 180
NYY-O       5x2,5 RE   0,6/1kV 4051204 120 15 380 0.29 63 95 190
NYY-O         5x4 RE   0,6/1kV 4051304 192 18 545 0.46 100 110 220
NYY-O         5x6 RE   0,6/1kV 4051404 288 19 685 0.69 150 120 240
NYY-O        5x10 RE   0,6/1kV 4051504 480 21 935 1.15 250 130 260
NYY-O        5x16 RE   0,6/1kV 4051604 768 24 1280 1.84 400 145 290
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.