BayEnergy® Power cables, PVC insulation, concentric conductor, PVC sheath

NYCY

multicore acc. to DIN VDE 0276


AT131_NYCY_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung16-Inhouse10-Verlegung im Freien, UV-Schutz beachten!30-Ölbeständig_bedingt50-Verlegung -5

optional

Verlegung -25 -30 -40 optionalUV-beständig optionalÖlbeständig optional

Standards

DIN VDE 0276-627 part 4H / HD 627 S1 and IEC 60502-1,
cores with black numbering printed.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are flame retardant and self-extinguishing according to DIN EN 50265-2-1 (IEC 60332-1-2) and free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

Technical Data

Rated voltage kV 0.6/1
Testing voltage kV 4
Cable temperature ºC
during laying (min)
after laying (max)


-5
+70

Max. permissible operating temperature (conductor) °C +70
Short-circuit temperature °C +160
Current carrying capacity
acc. to HD 603 S1:1996 4H
 

Application

For indoor and outdoor installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where protection against contact voltage is required in the case of mechanical damage. (See DIN VDE 0298-1.)

The cables are insensitive to occasional impacts of oils and fuels.

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
Y insulation made of polyvinyl chloride (PVC)
C Concentric Cu-conductor
Y outer sheath made of polyvinyl chloride (PVC)
J cable with green-yellow core
O cable without green-yellow core
RE circular conductor, solid
RM circular conductor, stranded
SM sector-shaped conductor, stranded

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

NYCY 8 x 2,5 RE/4 0,6/1 kV


Print Icon

BayEnergy® Power cables, PVC insulation, concentric conductor, PVC sheath

NYCY

multicore acc. to DIN VDE 0276

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
NYCY     7x1,5 RE/2,5  0,6/1kV 4153400 133 16 400 0.17 53 100 200
NYCY     7x2,5 RE/2,5  0,6/1kV 4146800 200 17 490 0.29 88 110 210
NYCY       7x4 RE/4    0,6/1kV 4147800 315 20 705 0.46 140 130 250
(N)YCY     7x6 RE/6    0,6/1kV 4148000 470 22 905 0.69 210 140 270
NYCY     8x1,5 RE/2,5  0,6/1kV 4122600 147 17 455 0.17 60 110 210
NYCY     8x2,5 RE/4    0,6/1kV 4154000 238 18 560 0.29 100 120 230
NYCY       8x4 RE/6    0,6/1kV 4148210 374 22 810 0.46 160 140 270
(N)YCY     8x6 RE/6    0,6/1kV 4148200 535 23 1010 0.69 240 140 280
(N)YCY    8x10 RE/10   0,6/1kV 4181000 902 26 1425 1.15 400 160 320
NYCY    10x1,5 RE/2,5  0,6/1kV 4152100 176 19 530 0.17 75 120 240
NYCY    10x2,5 RE/4    0,6/1kV 4155000 286 21 670 0.29 125 130 260
NYCY      10x4 RE/6    0,6/1kV 4152200 443 25 980 0.46 200 150 300
NYCY    12x1,5 RE/2,5  0,6/1kV 4146100 205 20 575 0.17 90 120 240
NYCY    12x2,5 RE/4    0,6/1kV 4147100 334 21 735 0.29 150 130 260
NYCY    12x2,5 RM/4    0,6/1kV 4120540 337 23 805 0.29 150 140 280
NYCY      12x4 RE/6    0,6/1kV 4136800 528 26 1080 0.46 240 160 320
(N)YCY    12x6 RE/10   0,6/1kV 4181100 829 28 1415 0.69 360 170 340
(N)YCY   12x10 RE/10   0,6/1kV 4180300 1300 31 1980 1.15 600 190 380
NYCY    14x1,5 RE/2,5  0,6/1kV 4146200 234 21 630 0.17 105 130 250
NYCY    14x2,5 RE/6    0,6/1kV 4147200 403 22 830 0.29 175 140 270
NYCY      14x4 RE/6    0,6/1kV 4136900 619 26 1210 0.46 280 160 320
(N)YCY    14x6 RE/10   0,6/1kV 4180200 965 29 1590 0.69 420 180 350
NYCY    16x1,5 RE/4    0,6/1kV 4145100 276 21 710 0.17 120 130 260
NYCY    16x2,5 RE/6    0,6/1kV 4155100 451 23 915 0.29 200 140 280
NYCY    16x2,5 RE/16   0,6/1kV 4155110 543 24 1010 0.29 200 150 290
NYCY    19x1,5 RE/4    0,6/1kV 4145300 320 22 780 0.17 143 140 270
NYCY    19x2,5 RE/6    0,6/1kV 4147400 523 24 1015 0.29 238 150 300
NYCY      19x4 RE/10   0,6/1kV 4137000 826 29 1535 0.46 380 180 350
NYCY    21x1,5 RE/6    0,6/1kV 4146300 369 24 865 0.17 158 150 290
NYCY    21x2,5 RE/10   0,6/1kV 4148300 571 26 1140 0.29 263 160 310
(N)YCY    21x4 RE/10   0,6/1kV 4180000 926 31 1690 0.46 420 190 370
NYCY    24x1,5 RE/6    0,6/1kV 4146400 413 26 965 0.17 180 160 310
NYCY    24x2,5 RE/10   0,6/1kV 4147500 696 28 1280 0.29 300 170 340
(N)YCY    24x4 RE/10   0,6/1kV 4180100 1035 34 1960 0.46 480 210 420
(N)YCY    24x6 RE/10   0,6/1kV 4180400 1559 38 2555 0.69 720 230 450
NYCY    27x1,5 RE/6    0,6/1kV 4146410 457 26 1035 0.17 203 160 320
NYCY    27x2,5 RE/10   0,6/1kV 4147510 736 29 1375 0.29 338 180 350
NYCY    30x1,5 RE/6    0,6/1kV 4146500 499 27 1110 0.17 225 170 330
NYCY    30x2,5 RE/10   0,6/1kV 4148100 840 29 1485 0.29 375 180 360
NYCY    37x1,5 RE/10   0,6/1kV 4136700 642 29 1330 0.17 278 180 350
NYCY    37x2,5 RE/10   0,6/1kV 4147710 971 32 1750 0.29 463 190 380
NYCY    37x2,5 RE/16   0,6/1kV 4147700 1065 32 1810 0.29 463 200 390
NYCY    40x1,5 RE/10   0,6/1kV 4147600 696 30 1415 0.17 300 180 360
NYCY    40x2,5 RE/10   0,6/1kV 4148700 1080 33 1870 0.29 500 200 400
NYCY    52x1,5 RE/10   0,6/1kV 4191000 865 33 1745 0.17 390 200 400
NYCY    52x2,5 RE/10   0,6/1kV 4191300 1342 37 2385 0.29 650 230 450
NYCY    61x1,5 RE/10   0,6/1kV 4119200 998 36 2020 0.17 454 220 430
NYCY    61x2,5 RE/10   0,6/1kV 4191400 1584 39 2700 0.29 763 240 470
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.