BayEnergy® Power cables, PVC insulation, lead sheath, PVC sheath
NYKY-J
1-3-cores acc. to DIN VDE 0265









Standards
DIN VDE 0265 and IEC 60502-1.
The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
They are flame retardant and self-extinguishing according to DIN EN 60332-1-2 (IEC 60332-1-2) and free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.
Technical Data
Rated voltage kV | 0.6/1 |
Testing voltage kV | 4 |
Cable temperature ºC during laying (min) after laying (max) |
|
Max. permissible operating temperature (conductor) °C | +70 |
Short-circuit temperature °C | +160 |
Current carrying capacity acc. to HD 603 S1-1994 3G during regular operation: table 14+15 in case of short-circuit: table 17 short-circuit duration max. 5s |
Application
For indoor and outdoor installation, in the ground, especially in applications where there is the influence of solvents, fuels, oils, gasoline or similar must be expected (e.g., refineries and gas stations).
Type Designation Codes
N | cables acc. to standard |
(N) | cables based on standard |
Y | insulation made of polyvinyl chloride (PVC) |
K | lead sheath |
Y | outer sheath made of polyvinyl chloride (PVC) |
J | cable with green-yellow core |
RE | circular conductor, solid |
RM | circular conductor, stranded |
SM | sector-shaped conductor, stranded |
Order Example
NYKY-J 3x1,5 RE 0,6/1 kV
BayEnergy® Power cables, PVC insulation, lead sheath, PVC sheath
NYKY-J
1-3-cores acc. to DIN VDE 0265
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.
*) N/A (not applicable) Cable is not subject to the Construction Products Regulation CPR.Due to the flame-retardant outer sheath, it could be classified as Eca. If necessary, inform our sales team.