Print Icon

BayCom® telecommunication cables with star quads

PE4-ALT-CLE

...x4x0,8 based on SBB CFF FFS 3001.52.1000


LT212_PE4-ALT-CLE_de

Standards

Based on SBB CFF FFS 3001.52.1000
halogen-free acc. to IEC 60754.1
smoke density acc. to IEC 61034.1/2

Technical Data

Conductor diameter mm 0.8
Loop resistance (DC at 20° C) Ω/km ≤ 73.5
Insulation resistance GΩ x km ≥ 10
Mutual capacitance (at 800 Hz) nF/km
mean value
tolerance limits

40±3
40±9
Capacitive coupling (at 800 Hz) pF/km
k1 max value/abs. mean value
k9-12 max value/abs. mean value

380/65
200/35
Ground couplings (at 800 Hz) pF/km
ea1, ea2 max value/abs. mean value

640/100
Dielectric strength V
core/core
core/screen

2000
2000
Temperature range for laying °C -5 to +50
Quad a-core b-core c-core d-core
Pilot quad white orange turquoise purple
Direction quad white green turquoise purple
Standard quad 1 white white turquoise purple
Standard quad 2 white blue turquoise purple

Application

Communication cable with stranded starquad, PE4 insulation (foam skin), ALT sheath, steel band armouring, and a halogen-free, flame-retardant and low-smoke outer sheath

Type Designation Codes

  solid conductor made of copper
PE4 conductor insulation made from cell PE with outer polyolefin layer (foam skin)
  cores stranded into quads, quads stranded into layers into conductor core
ALT laminated sheath made of PE with aluminium compound foil, black
CL steel band armouring
E outer sheath, halogen-free, flame-retardant, black with green longitudinal strips

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

PE4-ALT-CLE 10x4x0,8 mm D


Print Icon

BayCom® telecommunication cables with star quads

PE4-ALT-CLE

...x4x0,8 based on SBB CFF FFS 3001.52.1000

Product Bayka Order No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
mm kg/km daN min. mm min. mm  
PE4-ALT-CLE     2x4x0,8 mm D 5400135 16 345 40 160 210
PE4-ALT-CLE     3x4x0,8 mm D 5400140 16 355 55 160 210
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.