Print Icon

BayCom® telecommunication cables with star quads

PE4-ALT-CLT

...x4x0,8 acc. to SBB CFF FFS 3001.52.1000


LT20_PE4-ALT-CLT_de

Standards

SBB CFF FFS 3001.52.1000
halogen-free acc. to IEC 60754.1
smoke density acc. to IEC 61034.1/2

Technical Data

Conductor diameter mm 0.8
Loop resistance (DC at 20° C) Ω/km ≤ 73.5
Insulation resistance GΩ x km ≥ 10
Mutual capacitance (at 800 Hz) nF/km
mean value
tolerance limits

40±3
40±9
Capacitive coupling (at 800 Hz) pF/km
k1 max value/abs. mean value
k9-12 max value/abs. mean value

380/65
200/35
Ground couplings (at 800 Hz) pF/km
ea1, ea2 max value/abs. mean value

640/100
Dielectric strength V
core/core
core/screen

2000
2000
Temperature range for laying °C -5 to +50
Quad a-core b-core c-core d-core
Pilot quad white orange turquoise purple
Direction quad white green turquoise purple
Standard quad 1 white white turquoise purple
Standard quad 2 white blue turquoise purple

Application

Communication cable with stranded starquad, PE4 insulation (foam skin), ALT sheath, steel band armouring, and PE outer sheath

Type Designation Codes

  Solid conductor made of copper
PE4 conductor insulation made from cell PE with outer polyolefin layer (foam skin)
  cores stranded into quads, quads stranded into layers into conductor core
ALT laminated sheath made of PE with aluminium compound foil, black
CL steel band armouring
T outer sheath made of PE, black with green longitudinal strips

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

PE4-ALT-CLT 10x4x0,8 mm D


Print Icon

BayCom® telecommunication cables with star quads

PE4-ALT-CLT

...x4x0,8 acc. to SBB CFF FFS 3001.52.1000

Product Bayka Order No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
mm kg/km daN min. mm min. mm  
PE4-ALT-CLT     1x4x0,8 mm D   (313-16-301) 5400200 14 205 31 130 170
PE4-ALT-CLT     3x4x0,8 mm D   (313-16-303) 5400201 17 305 55 160 210
PE4-ALT-CLT     5x4x0,8 mm D   (313-16-305) 5400202 20 410 80 180 240
PE4-ALT-CLT    10x4x0,8 mm D   (313-16-310) 5400203 24 615 140 220 290
PE4-ALT-CLT    20x4x0,8 mm D   (313-16-320) 5400206 28 930 240 270 350
PE4-ALT-CLT    30x4x0,8 mm D   (313-16-330) 5400205 32 1235 340 290 390
PE4-ALT-CLT    50x4x0,8 mm D   (313-16-350) 5400220 42 1930 520 380 510
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.