Print Icon

BayCom® Telecommunication cables

A-2Y(L)2Y ... STIII

...x2x0,6 acc. to DIN VDE 0816


KT102_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung38-Querwasserdicht40-Geschirmt20-UV-beständig53-Verlegung -20

 


Standards

DIN VDE 0816-part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0,6
Conductor resistance (pair of cores) Ω/km ≤ 130
Insulation resistance GΩxkm ≥ 5
Mutual capacitance nF/km at 800 Hz ≤ 52
Capacitive couplings pF/300m at 800 Hz
k1
k9-12
the following applies to 2 quads according to DIN VDE 0816-1
k1
k9-12

≤ 400
≤ 100


≤ 800
≤ 300

Alternating voltage test 50 Hz
core-core V
core-screen V

500
2000
Operating voltage V ≤ 225
Cable temperature ºC
during laying
during operation

-20 to +50
-40 to +70

Application

As connection cable in subscriber networks and private branch exchanges, for telephony and signal transmission. Laying in the ground and in cable ducts, as well as threading into cable conduits.

Type Designation Codes

A outdoor cable
2Y core insulation made of polyethylene (PE)
(L)2Y laminated sheath, transversally watertight
St III starquad in the local cable
BD stranded in bundles
   

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-2Y(L)2Y 100x2x0,6 St III BD


Print Icon

BayCom® Telecommunication cables

A-2Y(L)2Y ... STIII

...x2x0,6 acc. to DIN VDE 0816

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2Y(L)2Y     6x2x0,6 STIII Bd 5415600 34 10 100 40 75 150
A-2Y(L)2Y    10x2x0,6 StIII Bd 5415800 57 11 135 50 90 180
A-2Y(L)2Y    20x2x0,6 StIII Bd 5416000 113 14 225 70 115 230
A-2Y(L)2Y    30x2x0,6 StIII Bd 5416200 170 16 300 95 120 240
A-2Y(L)2Y    40x2x0,6 StIII Bd 5416100 226 18 375 120 135 270
A-2Y(L)2Y    50x2x0,6 StIII Bd 5416500 283 19 455 150 150 300
A-2Y(L)2Y    70x2x0,6 StIII Bd 5416520 396 21 595 200 165 330
A-2Y(L)2Y   100x2x0,6 StIII Bd 5417500 565 24 810 280 190 380
A-2Y(L)2Y   150x2x0,6 STIII Bd 5402710 848 29 1215 410 225 450
A-2Y(L)2Y   200x2x0,6 StIII Bd 5402700 1131 34 1570 520 265 530
A-2Y(L)2Y   300x2x0,6 StIII Bd 5402730 1696 40 2280 740 310 620
A-2Y(L)2Y   400x2x0,6 STIII Bd 5402600 2262 46 2970 960 355 710
A-2Y(L)2Y   500x2x0,6 STIII Bd 5414510 2827 51 3700 1150 385 770
A-2Y(L)2Y  1000x2x0,6 STIII Bd 5402900 5655 71 7275 1750 425 850
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.