Download IconPrint Icon

BayCom® Telecommunication cables

A-2YF(L)2Y ... StIII

...x2x0,6 acc. to DIN VDE 0816


KT132_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung36-Längswasserdicht38-Querwasserdicht40-Geschirmt20-UV-beständig53-Verlegung -20

optional

Trinkwassergeeignet optionalHybrid optional

Standards

DIN VDE 0816-part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).Mutual capacitance nF/km at 800 Hz

Technical Data

Conductor diameter mm 0.6
Conductor resistance (pair of cores) Ω/km ≤ 130
Insulation resistance GΩxkm ≥ 1.5
Betriebskapazität nF/km bei 800 Hz ≤ 52
Capacitive couplings pF/km at 800 Hz
k1 (98%/100% of all values)
k9-12 (98%/100% of all values)

≤ 1333/2666
≤ 333/1000
Alternating voltage test 50 Hz
core-core V
core-screen V

500
2000
Operating voltage V ≤ 225
Cable temperature ºC
during laying
during operation

-20 to +50
-40 to +70

Application

As connection cable in subscriber networks and private branch exchanges, for telephony and data transmission. Suitable for laying in the ground and in cable ducts, as well as for threading into cable conduits. The cables are approved by VDE.

Type Designation Codes

2Y core insulation made of polyethylene (PE)
A outdoor cable
F cable core filled with petroleum jelly, longitudinally watertight
(L) 2Y laminated sheath, transversally watertight
St III starquad in the local cable
BD stranded in bundles

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-2YF(L)2Y 20x2x0,6 St III BD


Print Icon

BayCom® Telecommunication cables

A-2YF(L)2Y ... StIII

...x2x0,6 acc. to DIN VDE 0816

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YF(L)2Y     4x2x0,6 StIIIBd 5440400 23 11 105 30 85 170
A-2YF(L)2Y     6x2x0,6 StIIIBd 5440200 34 12 130 40 90 180
A-2YF(L)2Y    10x2x0,6 StIIIBd 5440500 57 13 180 50 105 210
A-2YF(L)2Y    20x2x0,6 StIIIBd 5440700 113 17 215 70 135 270
A-2YF(L)2Y    30x2x0,6 StIIIBd 5440900 170 20 425 95 150 300
A-2YF(L)2Y    40x2x0,6 StIIIBd 5441000 226 22 540 120 165 330
A-2YF(L)2Y    50x2x0,6 StIIIBd 5441400 283 24 655 150 190 380
A-2YF(L)2Y    70x2x0,6 StIIIBd 5441700 396 27 845 200 205 410
A-2YF(L)2Y   100x2x0,6 StIIIBd 5442000 565 31 1155 230 235 470
A-2YF(L)2Y   150x2x0,6 StIIIBd 5442300 848 37 1670 410 285 570
A-2YF(L)2Y   200x2x0,6 StIIIBd 5442800 1131 43 2250 520 325 650
A-2YF(L)2Y   300x2x0,6 StIIIBd 5443000 1696 51 3280 740 385 770
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.