BayCom® Telecommunication cables
A-02YSOF(L)2Y ... StIII
...x2x0,6 acc. to Bayka standard BayCom












Standards
Based on DIN VDE 0816.
The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2011/65/EU - RoHS 2.0 and Regulation No. 1907/2006 (REACH).
Technical Data
Conductor diameter mm | 0.6 |
Conductor resistance (pair of cores) Ω/km | ≤ 130 |
Insulation resistance GΩxkm | ≥ 1.5 |
Mutual capacitance nF/km at 800 Hz | ≤ 52 |
Capacitive couplings pF/km at 800 Hz k1 (98%/100% of all values) k9-12 (98%/100% of all values) |
≤ 1333/2666 ≤ 333/1000 |
Temperature ranges during laying before and after laying |
- 20 to +70 to+70 |
Application
As connection cable in subscriber networks and private branch exchanges, for telephony and data transmission. Suitable for laying in the ground and in cable ducts, as well as for threading into cable conduits. The cables are approved by VDE.
Type Designation Codes
A | outdoor cable |
02YS | core insulation made from cell PE with outer polyolefin layer |
OF | cable core with low-capacitance filling, transversally watertight |
(L)2Y | laminated sheath, transversally watertight |
StIII | starquad in the local cable |
BD | stranded in bundles |
Additional Informations
Design according to national and international standards
Design according to customer specifications
Order Example
A-02YSOF(L)2Y 20x2x0,6 StIII Bd
BayCom® Telecommunication cables
A-02YSOF(L)2Y ... StIII
...x2x0,6 acc. to Bayka standard BayCom
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.
*) N/A (not applicable) Cable is not subject to the Construction Products Regulation CPR
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.
*) N/A (not applicable) Cable is not subject to the Construction Products Regulation CPR