Print Icon

BayCom® Telecommunication cables

A-2Y(L)2Y ... STIII

...x2x0,8 acc. to DIN VDE 0816


KT103_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung38-Querwasserdicht40-Geschirmt20-UV-beständig53-Verlegung -20

optional

Trinkwassergeeignet optionalHybrid optional

Standards

DIN VDE 0816-part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.8
Conductor resistance (pair of cores) Ω/km ≤ 73.2
Insulation resistance GΩxkm ≥ 5
Mutual capacitance nF/km at 800 Hz ≤ 55
Capacitive couplings pF/300m at 800 Hz
k1
k9-12
the following applies to 2 quads according to DIN VDE 0816-1
k1
k9-12

≤ 400
≤ 100

 

≤ 800
≤ 300

Alternating voltage test 50 Hz
core-core V
core-screen V

500
2000
Operating voltage V ≤ 225
Cable temperature ºC
during laying
during operation

-20 to +50
-40 to +70

Application

As connection cable in subscriber networks and private branch exchanges, for telephony and signal transmission. Laying in the ground and in cable ducts, as well as threading into cable conduits.

Type Designation Codes

A outdoor cable
2Y core insulation made of polyethylene (PE)
(L)2Y laminated sheath, transversally watertight
St III starquad in the local cable
BD stranded in bundles
   

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-2Y(L)2Y 100x2x0,8 St III BD


Print Icon

BayCom® Telecommunication cables

A-2Y(L)2Y ... STIII

...x2x0,8 acc. to DIN VDE 0816

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2Y(L)2Y     2x2x0,8 STIII Bd 5416600 20 9 80 18 75 150
A-2Y(L)2Y     4x2x0,8 STIII Bd 5416800 40 11 125 30 90 180
A-2Y(L)2Y     6x2x0,8 STIII Bd 5417000 60 12 140 40 90 180
A-2Y(L)2Y    10x2x0,8 StIII Bd 5417200 101 14 200 60 105 210
A-2Y(L)2Y    20x2x0,8 StIII Bd 5417400 201 17 345 100 135 270
A-2Y(L)2Y    30x2x0,8 StIII Bd 5417600 302 20 480 150 150 300
A-2Y(L)2Y    40x2x0,8 StIII Bd 5413500 402 22 610 200 175 350
A-2Y(L)2Y    50x2x0,8 StIII Bd 5413700 503 24 740 250 190 380
A-2Y(L)2Y    70x2x0,8 StIII Bd 5413800 704 27 1000 340 205 410
A-2Y(L)2Y   100x2x0,8 StIII Bd 5414000 1005 32 1380 460 240 480
A-2Y(L)2Y   150x2x0,8 STIII Bd 5414100 1508 38 2070 660 295 590
A-2Y(L)2Y   200x2x0,8 STIII Bd 5414600 2011 44 2695 850 340 680
A-2Y(L)2Y   250x2x0,8 STIII Bd 5414610 2592 50 3370 1000 375 750
A-2Y(L)2Y   300x2x0,8 STIII Bd 5414620 3034 53 3965 1150 400 800
A-2Y(L)2Y   500x2x0,8 STIII Bd 5415000 5027 66 6460 1700 505 1010
A-2Y(L)2Y   600x2x0,8 STIII Bd 5415010 6032 73 7750 1900 550 1100
A-2Y(L)2Y   700x2x0,8 STIII Bd 5415020 7038 78 9300 0 0 0
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.