Print Icon

BayCom® Railway telecommunication cables

A-02YSF(L)2Y ... StIII
AJ-02YSF(L)2Y ... StIII

...x2x0,6 acc. to DB Dlk 1.013.151y


KT161_en

Standards

Dlk 1.013.151y and/or DIN VDE 0816-part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.6
Conductor resistance (pair of cores) Ω/km ≤130
Insulation resistance GΩxkm ≥ 1.5
Mutual capacitance at 800Hz nF/km ≤ 42
Capacitive couplings pF/km at 800 Hz
k1 (98%/100% of all values)
k9-12 (98%/100% of all values)

≤ 1333/2666
≤ 333/1000
Operating voltage V ≤ 225
Alternating voltage test 50 Hz
core-core Veff
core-screen Veff
 
500
2000
Temperature ranges
during laying, installing °C
before and after laying, installing °C

-20 to +50
-40 to +70

Application

As connection cable in subscriber networks and private branch exchanges, for telephony and data transmission. Suitable for laying in the ground and in cable ducts, as well as for threading into cable conduits. The cables are approved by VDE (certificate with production monitoring) and released for use in the area of operation of Deutsche Bahn AG.

Type Designation Codes

A outdoor cable
02YS conductor insulation made from cell PE with outer polyolefin layer
F cable core filled with petroleum jelly, longitudinally watertight
(L)2Y laminated sheath, transversally watertight
St III starquad in the local cable
Bd stranded in bundles
(H42) Mutual capacitance max value 42 nF/km

Special Designs

Design according to national and international standards
Design according to customer specifications

Order Example

A-02YSF(L)2Y 10x2x0,6 STIII Bd (H42)


Print Icon

BayCom® Railway telecommunication cables

A-02YSF(L)2Y ... StIII
AJ-02YSF(L)2Y ... StIII

...x2x0,6 acc. to DB Dlk 1.013.151y

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-02YSF(L)2Y   6x2x0,6 StIIIBd  (H 42) (00174233) 5489000 34 11 120 30 50 100
A-02YSF(L)2Y  10x2x0,6 StIIIBd  (H 42) (00174234) 5489200 57 12.5 165 40 50 100
A-02YSF(L)2Y  20x2x0,6 StIIIBd  (H 42) (00174235) 5489500 113 16.5 285 60 75 150
A-02YSF(L)2Y  30x2x0,6 StIIIBd  (H 42) (00174236) 5467500 170 19 395 85 75 150
A-02YSF(L)2Y  40x2x0,6 StIIIBd  (H 42) (00174237) 5467700 226 21 500 100 100 200
A-02YSF(L)2Y  50x2x0,6 StIIIBd  (H 42) (00174238) 5467900 283 23 605 130 100 200
A-02YSF(L)2Y  70x2x0,6 StIIIBd  (H 42) (00174239) 5468300 396 26.5 825 180 100 200
A-02YSF(L)2Y 100x2x0,6 StIIIBd  (H 42) (00174240) 5468500 565 30.5 1125 250 125 250
A-02YSF(L)2Y 150x2x0,6 StIIIBd  (H 42) (00174241) 5469000 848 37 1635 370 150 300
A-02YSF(L)2Y 200x2x0,6 StIIIBd  (H 42) (00174242) 5469500 1131 41.5 2120 440 175 350
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.