Print Icon

BayCom® Telecommunication cables ST I, trunk cable

A-02YSF(L)2YV
A-02YSF(L)2YB2Y
A-02YSF(L)2Y(SR)2Y

Branch cable acc. to Arcor TNP06 (DB AG)


LT13_A-02YSF(L)2Y_Arcor_de
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung36-Längswasserdicht38-Querwasserdicht50-Verlegung -5

 


Standards

Arcor TNP 06

Technical Data

Conductor diameter mm 0.9 / 1.4
Conductor resistance (pair of cores) Ohm/km ≤ 56.6 / ≤ 23.4
Insulation resistance GOhmxkm ≥ 10 / ≥ 10
Mutual capacitance at 800Hz nF/km  
100 % of all values ≤ 38 / ≤ 40.3
85 % of all values ≤ 34 / ≤ 36
Capacitive coupling k1 pF at 800 Hz  
100 % of all values ≤ 400
80 % of all values ≤ 110
Capacitive coupling k9-12 pF at 800 Hz  
100 % of all values ≤ 400
80 % of all values ≤ 110
Alternating voltage test 50 Hz  
core-core Veff 500 / 500
core-screen Veff 2000 / 2000

Application

For general application as standardised branch cane in existing track communication cable systems in paper-metal sheath design (according to Dlk. 1.01.106 - Deutsche Bahn AG) and in new systems installed using cables according to technical data sheet Arcor TNP 05.

For laying in the ground, in pipe conduits and trough channels in accordance with the applicable regulations. All trunk lines of the cables can be interconnected surge-free with trunk lines of the same nominal conductor diameter of the cables according to Dlk 1.01.106 (paper-metal sheath cables of the existing network).

Type Designation Codes

A outdoor cable according to standard
02YS conductor insulation made from cell PE with outer polyolefin layer (foam skin)
F cable core filled with petroleum jelly, longitudinally watertight
OF cable core filled with filling material with low relative permittivity, longitudinally watertight
TF cable core dry filled with swelling yarns and swelling fleeces, longitudinally watertight
(L)2Y laminated sheath, transversally watertight
(L)2YV reinforced laminated sheath, transversally watertight
B steel tape armouring
(SR) steel channel sheath
2Y outer sheath made of PE
STI starquad in track cable quality (increased electrical properties)
LG stranded in layers

Order Example

A-02YSF(L)B2Y 2x4x1,4 / 2x4x0,9 STI TNP 06


Print Icon

BayCom® Telecommunication cables ST I, trunk cable

A-02YSF(L)2YV
A-02YSF(L)2YB2Y
A-02YSF(L)2Y(SR)2Y

Branch cable acc. to Arcor TNP06 (DB AG)

Product CPR DoP *) Bayka Order No. Customer Order-No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-02YSF(L)2YV      3x4x0,9 STI ARCOR TNP 06 N/A 5202500 00794969 83 17 240 42 85 170
A-02YSOF(L)2YV         3x4x0,9 StI Lg   ARCOR TNP 06 N/A 5222700 00794970 83 17 240 42 85 170
A-02YSTF(L)2YV     3x4x0,9 STI ARCOR TNP 06 N/A 5203000 00794971 83 17 240 42 85 180
A-02YSF(L)2YV    2x4x1,4 StI   + 2x4x0,9 StI Lg  (00614056) N/A 5482700 00614056 177 20 410 0 0 0
A-02YSOF(L)2YV         2x4x1,4 + 2x4x0,9 StI Lg ARCOR TNP 06 N/A 5422800 00794974 180 21 420 85 105 210
A-02YSTF(L)2YV       2x4x1,4 /  2x4x0,9 STI ARCOR TNP 06 N/A 5201200 00794975 180 21 420 85 105 210
A-02YSF(L)2Y(SR)2Y     3x4x0,9 STI ARCOR TNP 06 N/A 5203120 00794979 83 20 350 85 150 200
A-02YSF(L)2YB2Y        3x4x0,9 STI ARCOR TNP 06 N/A 5203130 00794988 83 20 350 85 150 200
A-02YSOF(L)2Y(SR)2Y    3x4x0,9 STI ARCOR TNP 06 N/A 5485220 00794980 83 20 350 85 150 200
A-02YSOF(L)2YB2Y       3x4x0,9 STI ARCOR TNP 06 N/A 5485210 00794989 83 20 350 85 150 200
A-02YSTF(L)2Y(SR)2Y    3x4x0,9 STI ARCOR TNP 06 N/A 5203110 00794981 83 20 350 85 150 200
A-02YSTF(L)2YB2Y       3x4x0,9 STI ARCOR TNP 06 N/A 5203100 00794990 83 20 350 85 150 200
A-02YSF(L)2Y(SR)2Y     2x4x1,4 STI + 2x4x0,9 StI Lg ARCOR TNP N/A 5485100 00794982 180 24 540 170 180 240
A-02YSF(L)2YB2Y    2x4x1,4 StI + 2x4x0,9 StI   ARCOR TNP 06 N/A 5482800 00794992 180 24 540 170 180 240
A-02YSTF(L)2Y(SR)2Y  2x4x1,4 /  2x4x0,9 STI ARCOR TNP 06 N/A 5211110 00794986 180 24 540 170 180 240
A-02YSTF(L)2YB2Y     2x4x1,4 /  2x4x0,9 STI ARCOR TNP 06 N/A 5201100 00794994 180 24 540 170 180 240
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.
*) N/A (not applicable) Cable is not subject to the Construction Products Regulation CPR