BayCom® Telecommunication cables ST I (KOM cables)

AJ-02YSTF(L)2YDB2Y

with inductive protection acc. to TR Kom-Netz WSV


LT103_AJ-02YSTF(L)2YDB2Y_de
WSVVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung36-Längswasserdicht38-Querwasserdicht40-Geschirmt44-Nagetierschutz46-Robust50-Verlegung -5

 


Standards

According to WSV Technical Specification VV-WSV 2504-IV/4.2.1
Technical Guideline for planning, construction, and maintenance of communication network systems of WSV (TG Com. Network WSV)

Technical Data

Conductor diameter mm 0.9
(LF)
1.2
(HF)
1.4
(LF)
1.4
(HF)
Conductor resistance (pair of cores) Ω/km ≤ 56.6 ≤ 31.8 ≤ 23.4 ≤ 23.4
Resistance difference Ω/km ≤ 0.18 ≤ 0.18 ≤ 0,18 ≤ 0,18
Mutual capacitance at 800Hz nF/km ≤ 38 ≤ 33 ≤ 40,3 ≤ 38
Insulation resistance (L>200m) GΩxkm ≥ 10 ≥ 10 ≥ 10 ≥ 10
Capacitive coupling at 800 Hz pF/km
k1 *)
k9-12 *)
*) 20 % of all values up to 400 pF/km


≤ 110
≤ 110


≤ 110
≤ 110


≤ 110
≤ 110


≤ 110
≤ 110
Characteristic impedance (at 120 kHz)  Ω   150   131
Wave attenuation dB/km
at 108 kHz
at 1 MHz
 
≤ 2,4
≤ 6,7
 

≤ 6,0
Near-end crosstalk attenuation NEXT (at 1 MHz) dB
within the quad
quad/quad
 

≥ 45
≥ 62
 

≥ 45
≥ 58
Far-end crosstalk attenuation
(at 1 MHz) dB
within the quad
 

≥ 45
 

≥ 45
Alternating voltage test V
core/core
core/screen

500
2000

500
2000

500
2000

500
2000

Application

Long-distance communication cables for larger distances in the area of the Federal Waterways and Shipping Administration.

For general cabling across larger distances in the case of new track constructions, as replacement for paper-insulated long-distance cables (track communication cables) with St, F, and TF construction elements for laying in the ground, in tray channels and pipe conduits in accordance with the applicable regulations.

All trunk lines of the cables according to these Technical Specifications can be interconnected surge-free with trunk lines of the same nominal conductor diameter of the WSV cable types of the existing communication network.

Type Designation Codes

AJ outdoor cable with inductive protection
02YS conductor insulation made from cell PE with outer polyolefin layer (foam skin)
TF cable core dry filled, longitudinally watertight
(L)2Y laminated sheath, transversally watertight
D concentric screen made of Cu wires
B steel tape armouring
2Y outer sheath made of PE
STI starquad in track cable quality (increased electrical properties)
A, B, C reduction factor series

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

AJ-02YSTF(L)2YDB2Y 4x4x1,2 /  7x4x1,4 / 10x4x0,9 STI


Print Icon

BayCom® Telecommunication cables ST I (KOM cables)

AJ-02YSTF(L)2YDB2Y

with inductive protection acc. to TR Kom-Netz WSV

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius repeated Bending radius one-off
kg/km mm kg/km daN min. mm min. mm  
AJ-02YSTF(L)2YDB2Y   6x4x1,4 /  2x4x1,2 STI  A  WSV2504 5220102 625 39 1800 380 780 590
AJ-02YSTF(L)2YDB2Y   6x4x1,4 /  2x4x1,2 STI  B  WSV2504 5220103 776 40 1950 422 800 600
AJ-02YSTF(L)2YDB2Y   6x4x1,4 /  2x4x1,2 STI  C  WSV2504 5220104 1223 43 2820 628 860 650
AJ-02YSTF(L)2YDB2Y   7x4x1,4 / 3x4x1,2/ 8x4x0,9 STI A WSV2504 5220132 968 47 2440 573 940 710
AJ-02YSTF(L)2YDB2Y   7x4x1,4 / 3x4x1,2/ 8x4x0,9 STI B WSV2504 5220133 1166 48 2650 657 960 720
AJ-02YSTF(L)2YDB2Y   7x4x1,4 / 4x4x1,2/10x4x0,9 STI A WSV 5220152 1083 59 3650 684 500 370
AJ-02YSTF(L)2YDB2Y   7x4x1,4 / 4x4x1,2/10x4x0,9 STI B WSV 5220153 1291 59 3920 766 500 380
AJ-02YSTF(L)2YDB2Y   7x4x1,4 / 4x4x1,2/10x4x0,9 STI C WSV 5220154 1993 61 5150 954 530 400
AJ-02YSTF(L)2YDB2Y  13x4x1,4 /  3x4x1,2 STI  A  WSV2504 5220122 1108 49 2700 651 980 740
AJ-02YSTF(L)2YDB2Y  13x4x1,4 /  3x4x1,2 STI  B  WSV2504 5220123 1294 50 2900 732 1000 750
AJ-02YSTF(L)2YDB2Y  13x4x1,4 /  3x4x1,2 STI  C  WSV2504 5220124 1817 52 3940 953 1040 780
AJ-02YSTF(L)2YDB2Y  14x4x1,4 / 4x4x1,2/13x4x0,9 STI A WSV2504 5220142 1670 50 2700 575 1000 750
AJ-02YSTF(L)2YDB2Y  14x4x1,4 / 4x4x1,2/13x4x0,9 STI B WSV2504 5220143 1860 50 2910 654 1000 750
AJ-02YSTF(L)2YDB2Y  14x4x1,4 / 4x4x1,2/13x4x0,9 STI C WSV2504 5220144 2501 52 4040 884 1040 780
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.